✨ Welcome to the new Discount Equipment site — same 36-year team, freshly redesigned.
36 Years of Industry Leadership · Trusted by Contractors Across America · U.S. Freight & Exporter-Friendly
MultiQuip

Multiquip GB12BW GloBug Light Tower Balloon System 400W Metal Halide Lamp

Part number
GB12BW
Model
GB12BW
Year
2/1/2026
Condition
New
$2475.88List $3415.00Save $939.12

MultiQuip orders have a $50.00 minimum (Multiquip family)

Genuine OEMShips nationwideExpert support
Multiquip GB12BW GloBug Light Tower Balloon System 400W Metal Halide Lamp: The GB12 Series combines high quality, diffused lighting with the value of 400W metal halide lamps. This GloBug series supports security, emergency response, road work, construction, and special events. - Metal halide lamp - single 400 watt lamp for excellent illumination. 3400°K pure white light - Minimal power - only 4 Amps of 115V power - Expansive light coverage - up to 79 feet - 360° glare-free illumination with standard fire retardant (UL94 VTM Standard Test) balloon - Universally adaptable to all AC power supplies - accepts 50/60Hz, 100-240V - Reflective balloon top - redirects light towards work area - Self-inflating balloons are easy to install and inflate in less than 20 seconds - Three-stage mast - extends up to 10' 5" - Aluminum tripod stand model provides three outriggers for solid stabilization - Optional message strip available - Easy transport and storage - vinyl carrying cases included
Multiquip GB12BW GloBug Light Tower Balloon System 400W Metal Halide Lamp: •Light weight electronic ballast built inside the lamp housing •Air-assist mast lowering system protects light bulb •Quick and easy setup; balloon inflates in less than 30 econds •360º glare-free lighting •Carrying cases included for easy transportation
Multiquip GB12BW GloBug Lighting System: Mount Type: Tripod, Aluminum, 2-Stage Air-Assisted Mast Max. Height: 10.5' Total Weight: 34 lb. Wind Limits: 25 MPH Lamp Assembly: Balloon: 33.5" x 21" Lamp (W): 400W Metal Halide Lumens: 34,000 Voltage (V): 115 Current (A): 4A @115V Hertz (Hz): 50-60 Dimmer Switch: 100/200/300W Min. Generator: 3450 W
Multiquip GB12BW GloBug GB12BW/BS/BP LIGHTING SYSTEM — RULES FOR SAFE OPERATION WARNING - READ THIS MANUAL Failure to follow instructions in this manual may lead to Serious Injury or even Death. This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating GloBug Lighting System. The following safety guidelines should always be used when operating any GloBug Lighting System: GENERAL SAFETY DO NOT operate or service this equipment before reading this entire manual. This equipment should not be operated by persons under 18 years of age. NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job. NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine NEVER operate this equipment under the influence of drugs or alcohol . Whenever necessary, replace nameplate, operation and safety decals when they become difficult read. Manufacturer does not assume responsibility for any accident due to equipment modifications. NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result ALWAYS make sure that the GB12BW (tripod) lighting system is placed on secure firm level ground so that it cannot slide or shift around, endangering workers. Also keep the immediate area free of bystanders. ALWAYS keep area behind lighting system clear of people while raising and lowering mast. To prevent the lighting system from overturning, NEVER use in winds that exceed 22 mph(10m/s). To prevent the GB12BW (tripod) lighting system from tipping, ALWAYS place tripod on a firm flat surface. Surface slant should not exceed 5 degrees. The GloBug lighting system should only be used in temperatures between 23°-104° Fahrenheit (-5° to 40° Celsius). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life. NEVER use any GloBug lighting system in rain, snow or areas of high humidity that could generate electrical storms. MAST SAFETY When raising or lowering the mast, keep hands and fingers clear of the various mast sections, this will prevent hands and fingers from getting pinched. CHECK the mast for any deformations. Replace mast if defective. NEVER attach anything to the mast. ALWAYS lower the mast when not in use, or if high winds or electrical storms are expected in the area. When transporting the tripod lighting system, always place tripod in the stow position, then place tripod into its carrying case. ALWAYS remove the balloon/lamp assembly from the mast when transporting any of the GloBug lighting systems. This will prevent damage to the bulb due to vibration. NEVER leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon's nylon cover. ALWAYS place the balloon inside its protective cover during transport. Be sure the cover is secured tightly around the balloon/lamp assembly. BALLOON SAFETY AND CARE To prevent serious burns, NEVER touch or unzip the balloon envelope when the lamp is on. To prevent the balloon from deformation, NEVER use any GloBug lighting system in strong winds. DO NOT place the balloon inside its protective cover until the lamp has had a sufficient amount of time to cool down. This will prevent the balloon's nylon cover from being burned (touching the lamp surface). ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements. DO NOT use a damaged balloon. Replace balloon immediately if damaged. In addition, a damaged balloon will not inflate properly, and may become more damaged by touching the hot lamp surface. ALWAYS keep the balloon away from sharp objects and excessive amounts of heat (fire!). DO NOT use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken the balloon will become unusable. LAMP SAFETY AND CARE NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp. ALWAYS make sure the lamp surface is clean and dry. ALWAYS replace with MQ recommended type lamp. See parts section of this manual. NEVER use force when installing the lamp. Excessive force could cause the lamp to break causing bodily harm. ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard. NEVER attempt to replace lamp with the power on. Always unplug the power cord from the generator or power source when changing the lamp. NEVER unplug the lamp's AC power cable during operation. ALWAYS allow a sufficient amount of time for the lamp to cool before changing. The possibility exists of severe burns. ALWAYS have a trained technician to install and remove lamp, or replace any damaged fixture wiring. DANGER - Grounding All GloBug lighting systems are equipped with a ground pin on the power plug. For your protection. ALWAYS complete the grounding path. NEVER insert the AC power plug into a 2-prong receptacle to operate any GloBug lighting system. When applying power to the lighting system, always connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of Electrical Shock, Electrocution, and even Death if the lighting system is not grounded. DANGER - Electric Shock Hazards ALWAYS keep electrical cords in good condition. Worn, bare or frayed wiring can cause electrical shock, thus causing Bodily Harm or even Death. NEVER grab or touch a live power cord with wet hands, the possibility exists of Electrical Shock, Electrocution, and even Death! DANGER - Electric Shock Hazards NEVER operate any of the GloBug lighting systems or handle any electrical equipment while standing in water, while barefoot, while hands are wet, or in the rain. A dangerous electrical shock could occur causing Severe Bodily Harm or even Death. DANGER - Overhead Obstructions ALWAYS make sure the area above any GloBug lighting system is open and clear of overhead power lines and other obstructions. The mast can extend in excess of 13 ft. (4 meters) when an optional extension pole is used. Contact with overhead power lines or other obstructions could result in electrical shock, electrocution, causing equipment damage, Serious Injury or Death! Maintenance Safety NEVER lubricate components or attempt service on any running GloBug lighting system. ALWAYS allow the GloBug lighting system a proper amount of time to cool before servicing. Keep all GloBug lighting systems in proper working condition. Fix damage to any GloBug lighting system immediately and always replace broken or defective parts. ALWAYS use the required tool for the job application. Using damaged or worn tools or using tools inappropriate for the required application is very dangerous, and may cause damage to the machine and service personnel. Make sure to use the appropriate tool for the specific job. Emergencies ALWAYS know the location of the nearest fire extinguisher ALWAYS know the location of the nearest first aid kit. In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in case of an emergency