**NO LONGER AVAILABLE** Multiquip GBS GloBug, Off-Set Equip Mount, 1KW E-ballast, 1000W Metal Halide Light The GBS GloBug is ideal for mobile construction. Utilizing the flexible clamp assembly, the design allows installation of the unit at any angle, is safer for construction crews, and complies with many State DOT requirements for jobsite illumination. The GBS is the complete 1000W diffused balloon bag assembly and includes a 90º off-set pole set and mounting hardware. It allows the user to adapt the GloBug to a piece of construction equipment to provide glare-free lighting for the equipment operator and road crew. The unit requires very little power requirements (9.3A 115V), and provides exceptional 360º shadow-free lighting that supports security, special events, construction, and emergency response applications. The spherical projection of glare-free light luminous extends over 150'.
**NO LONGER AVAILABLE** Multiquip GBS Equipment Mount Multiquip GBS GloBug, Off-Set Equip Mount, 1KW E-ballast, 1000W Metal Halide Light • GBS Series - Includes GBP 1,000 watt lamp, 90º pole set, flexible mounting brackets and hardware • 107,000 lumen output • Requires only 9.3A @ 115V power requirements • Safe for vehicle traffic - Drivers not blinded by intense glare of conventional light towers • Improved visibility and elimination of blind spots on the job site
Multiquip GBS GloBug, Balloon Light Mounted Required Generator Sizing..... 1200 W Voltage..... 115 V Amps..... 9.3 A @ 115V A Frequency..... 50-60 Hz Lamp Type..... 1,000 watt Metal Halide Frosted Bulb (x1) Total Luminous Flux..... 107,000 lm Outriggers..... N/A
Multiquip GBS GloBug, Balloon Light Mounted GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the influence of drugs or alcohol. ALWAYS check the equipment for loosened threads or bolts before starting. DO NOT use the equipment for any purpose other than its intended purposes or applications NOTICE This equipment should only be operated by trained and qualified personnel 18 years of age and older. Whenever necessary, replace nameplate, operation and safety decals when they become difficult read. Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties. NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result. ALWAYS know the location of the nearest fire extinguisher. ALWAYS know the location of the nearest first aid kit. ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency. LIGHTING SYSTEM SAFETY WARNING NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties. CAUTION NEVER attempt service on a running machine. NOTICE To prevent the lighting system from overturning, NEVER use in winds that exceed 22 mph (10 m/s). The lighting system should only be used in temperatures between 23° to 104°F (-5° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life. ALWAYS keep the lighting system in proper running condition. Fix damage to lighting system and replace any broken parts immediately. ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel. LAMP SAFETY WARNING NEVER attempt to replace lamp with the power on. Always unplug the power cord from the generator or power source when changing the lamp. ALWAYS allow a sufficient amount of time for the lamp to cool before changing. The possibility exists of severe burns. CAUTION NEVER use force when installing the lamp. Excessive force could cause the lamp to break, causing bodily harm. NOTICE NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp. ALWAYS make sure lamp surface is clean and dry. ALWAYS replace with MQ recommended type lamp. See parts section of this manual. If applicable, ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard. NEVER unplug the lamp’s AC power cable during operation. ALWAYS have a trained technician to install and remove lamp or replace any damaged fixture wiring. BALLOON SAFETY WARNING To prevent serious burns, NEVER touch or unzip the balloon envelope when the lamp is on CAUTION ALWAYS keep the balloon away from sharp objects and excessive amounts of heat. NOTICE To prevent balloon deformation, NEVER use lighting system in strong winds. DO NOT place the balloon inside its protective cover until the lamp has had a sufficient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface). ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements. Replace balloon immediately if damaged. A damaged balloon will not inflate properly, and may become more damaged by touching the hot lamp surface. DO NOT use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable. GENERATOR SAFETY If using a generator to power lighting system, refer to applicable generator manual safety information section ELECTRICAL SAFETY DANGER Lighting system is equipped with a ground pin on the power plug. For your protection, ALWAYS complete the grounding path. NEVER insert the AC power plug into a 2-prong receptacle to operate lighting system. When applying power to the lighting system, ALWAYS connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of electrical shock, electrocution and even death if the lighting system is not grounded. NEVER operate lighting system or handle any electrical equipment while standing in water, while barefoot, while hands are wet or in the rain. A dangerous electrical shock could occur, causing severe bodily harm or even death. ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical shock, electrocution and even death. Power Cord/Cable Safety DANGER NEVER let power cords or cables lay in water. NEVER use damaged or worn cables or cords. Inspect for cuts in the insulation NEVER grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death. Make sure power cables are securely connected. Incorrect connections may cause electrical shock and damage to the lighting system. NOTICE ALWAYS make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual. LOADING AND UNLOADING Cart Type - With Lifting Hook If lighting system is equipped with a transport lifting hook, refer to the following safety information. CAUTION Before lifting, make sure that lighting system parts are not damaged and screws are not loosened or lost. ALWAYS make sure crane or lifting device has been properly secured to lifting hook of the equipment. NEVER lift the equipment while lighting system is running. Make sure the mast is completely lowered before lifting the lighting system. Use adequate lifting cable (wire or rope) of sufficient strength. Use one point suspension hook and lift straight upwards. Never allow any person or animal to stand underneath the equipment while lifting. DO NOT lift machine to unnecessary heights. Cart Type - No Lifting Hook If lighting system is not equipped with a transport lifting hook and the mast is removable, refer to the following safety information. Before lifting, make sure that the mast and lamp are removed as described in the manual. The cart can be safely lifted by two persons to the transport vehicle. TRANSPORTING SAFETY NOTICE When transporting the lighting system, if applicable, always place in stow position and place mast in its carrying case. ALWAYS remove balloon/lamp assembly from the mast when transporting lighting system. This will prevent damage to the bulb due to vibration. NEVER leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon’s nylon cover. ALWAYS place balloon inside its protective cover during transport. Be sure the cover is secured tightly around the balloon/lamp assembly